ST-i3 Plus
Version with OpenTherm and solar system. Modulating control of three mixing valves and their pumps, the hot water pump and the solar collectors according to the outdoor temperature and a weekly schedule.
- 3
- mixing valves with pumps
- OpenTherm
- communication with the boiler
- Solar
- PT-1000 collector sensor

Functions
What the ST-i3 Plus can do
| Mixing valves, modulating control | 3 |
|---|---|
| Mixing circuit pumps | 3 |
| Domestic hot water pump | ✓ |
| OpenTherm for the boiler | ✓ |
| Solar system, PT-1000 collector sensor | ✓ |
| Weather-compensated control | ✓ |
| Weekly schedule | ✓ |
| Return temperature protection | ✓ |
| Potential-free outputs, configurable | 2 |
| Voltage outputs, configurable | 2 |
| 0–10 V outputs | 2 |
| PWM signal | ✓ |
| Temperature sensors | 6 + outdoor + collector |
| On/off room thermostats | 3 |
| RS room thermostats | 1 |
| +2 valves with extension module | ✓ |
| Internet, with additional module | ✓ |
Technical data
The same for both versions
| Power supply | 230 V ±10%, 50 Hz |
|---|---|
| Max. consumption | 10 W |
| Ambient temperature | 5–50 °C |
| Sensor range | −30…99 °C |
| Setting range | 8–90 °C |
| Output load | 0.5 A |
| Fuse | 6.3 A |
| Display | 4.3″ colour, touch |
| Housing | white (Plus), grey (Lite) |
Optional accessories
- Extension module for 2 more mixing valves
- Ethernet or Wi-Fi internet module for control from a phone app
- Room thermostats with RS communication
- On/off room thermostats
Need an ST-i3?