TD Mini
Compact 1″ manifold for 2 to 5 circuits, with outlets upwards or both upwards and downwards.
- Circuits
- 2–5
- Connection
- 1″
- Output
- 25 kW
- Centre distance
- 125 mm

The manifold carries water from the boiler or hydraulic separator to the pump groups. The outlets are at a 125 mm centre distance, so TPG groups mount directly onto it.
Compact 1″ manifold for 2 to 5 circuits, with outlets upwards or both upwards and downwards.
For 2 to 8 circuits. Outlets upwards, downwards or both.
Same 125 mm format, with a 1½″ connection for higher outputs.
2″ connection and 150 mm centre distance, for large boilers and buildings with many circuits.
| Circuits | 2 to 8 |
|---|---|
| Connections | 1″ · 1¼″ · 1½″ · 2″ |
| Output ΔT 10 K | 25–175 kW |
| Output ΔT 20 K | up to 350 kW |
| Centre distance | 125 mm · 150 mm on TD 150 |
| Mounting | wall |
Technical data are for guidance only. Exact values for each model are given in the quote.