Smart-Tech · 5 devices

Smart-Tech controllers

Stand-alone controllers for heating circuits: they run valves and pumps according to the outdoor temperature and a weekly schedule, control the hot water pump and provide return temperature protection. ST-i1 for one circuit, ST-i2 Plus for two, ST-i3 for three, ST-L4 WiFi for underfloor and radiator heating zones.

ST-i1ST-i2 PlusST-i3 PlusST-i3 LiteST-L4 WiFi
Product photos. The final appearance may differ.
Comparison

ST-i1, ST-i2 Plus, ST-i3 Plus, ST-i3 Lite
and ST-L4 WiFi

ST-i1 runs one circuit with a mixing valve, plus hot water. ST-i2 Plus runs two circuits, with OpenTherm and a touchscreen. ST-i3 runs three circuits: Plus adds OpenTherm and a solar system, Lite adds a boiler cascade and cooling. ST-L4 WiFi controls underfloor and radiator heating zones.

FunctionST-i1 →ST-i2 Plus →ST-i3 Plus →ST-i3 Lite →ST-L4 WiFi →
Heating zones1 circuit2 circuits3 circuits3 circuits8 zones: 4 underfloor + 4 radiator
Mixing valves, modulating control1, up to 3 with modules2, up to 4 with modules33–
Mixing circuit pumps123––
Domestic hot water pump✓✓ anti-legionella✓✓ anti-legionella–
OpenTherm for the boiler–✓✓––
Solar system, PT-1000 collector sensor––✓––
Cascade of 3 boilers, on/off–✓–✓–
Heating and cooling–✓–✓–
Weather-compensated control✓✓✓✓–
Weekly schedule✓✓✓✓✓
Return temperature protection✓✓✓✓–
Potential-free outputs, configurable12221
Voltage outputs, configurable–2214, for actuators
0–10 V outputs–22––
PWM signal––✓––
Temperature sensorsboiler, return, valve, outdoor, DHWboiler, return, 2 valves, outdoor, DHW6 + outdoor + collectorDHW, outdoor, valves, return, boilerwired or wireless, per zone
On/off room thermostats✓333–
RS room thermostats✓✓13 + 1 with display–
+2 valves with extension module✓✓✓✓–
Internet, with additional module✓✓✓✓✓ built-in Wi-Fi
DisplayLCD4.3″ colour touch4.3″ colour touch4.3″ colour touchLCD
Software update via USB–✓–✓–

– function not listed for this model.

Products

Choose a device

Controller for 1 circuit and hot water

ST-i1

Controller for one three- or four-way mixing valve and its pump, plus the hot water pump, based on the DHW cylinder sensor. It controls according to the outdoor temperature and a weekly schedule, provides return temperature protection and switches on the heat source via a potential-free contact.

mixing, up to 3 with modules
1 valve
valve and hot water
2 pumps
weather compensation
Outdoor
Technical data →
Controller for 2 circuits with OpenTherm

ST-i2 Plus

Controller for two mixing valves with their pumps and the hot water pump, with a colour touchscreen and OpenTherm communication with a gas boiler. It controls according to the outdoor temperature and a weekly schedule, provides return temperature protection and can run boilers in cascade.

mixing, up to 4 with modules
2 valves
communication with the boiler
OpenTherm
colour touchscreen
4.3″
Technical data →
Controller with OpenTherm and solar system

ST-i3 Plus

Version with OpenTherm and solar system. Modulating control of three mixing valves and their pumps, the hot water pump and the solar collectors according to the outdoor temperature and a weekly schedule.

mixing valves with pumps
3
communication with the boiler
OpenTherm
PT-1000 collector sensor
Solar
Technical data →
Controller for cascades and cooling

ST-i3 Lite

Version for cascades and cooling. Modulating control of three mixing valves, the hot water pump with anti-legionella protection and up to three boilers in cascade.

mixing valves
3
in cascade, on/off
3 boilers
and heating, in the same controller
Cooling
Technical data →
Controller for mixed heating, 8 zones, Wi-Fi

ST-L4 WiFi

Wi-Fi controller for mixed systems: controls 4 underfloor heating zones, 4 radiator zones and the heat source. The first 4 zones accept wired or wireless sensors and thermostats, the others wireless only.

4 underfloor + 4 radiator
8 zones
built-in module
Wi-Fi
thermostats and sensors
Cable / radio
Technical data →
Pump groups

HYDEO pump groups for ST-i1, ST-i2 Plus and ST-i3

Ready-to-install HYDEO groups with a circulation pump, thermometers on flow and return, and ball valves. ST-i1 runs one group for a heating circuit and one for the DHW cylinder, ST-i2 Plus two groups for heating circuits and one for the DHW cylinder, ST-i3 up to three groups for heating circuits.

With mixing valve

TPG-M

For underfloor heating or radiators, with weather-compensated water temperature. The actuator and pump are run by the controller.

Technical data →
Direct, no mixing

TPG-D

For radiators or a DHW cylinder supplied directly from the heat source. The controller switches the pump on and off.

Technical data →
With thermostatic valve

TPG-T

For underfloor heating without an actuator: you set the temperature on the valve, the controller runs the pump.

Technical data →

Quote for Smart-Tech controllers