Technical catalogue: hydraulic systems
All HYDEO pump groups, manifolds, separators and modules, with technical data for each version. Insulated metal housings for the boiler room.
Products with technical data by family
HYDEO TPG pump groups
Pre-assembled pump groups for one heating circuit, with 125 mm centre distance. They mount directly onto TD and TDS manifolds.
General data
- Centre distance
- 125 mm
- Operating pressure
- up to 6 bar
- Thermometers
- 0–120 °C
- Heating medium
- water or water-glycol
- Pump installation length
- 130 mm (1″) · 180 mm (1¼″)
- Circulation pump
- of your choice
Models
| Model | Type | Connection | Output ΔT 10 / 20 K | Kvs | Height × width × depth | Volume |
|---|---|---|---|---|---|---|
| TPG-D 1″ | direct | 1″ | 20 / 40 kW | 10.2 m³/h | 353 × 261 mm | 0.32 l |
| TPG-D 1¼″ | direct | 1¼″ | 45 / 85 kW | 16.3 m³/h | 471 × 296 × 160 mm | 0.9 l |
| TPG-T 1″ | thermostatic valve 25–55 °C | 1″ | 15 / 30 kW | 3.5 m³/h | 353 × 261 mm | 0.34 l |
| TPG-M 1″ | three-way mixing valve | 1″ | 20 / 40 kW | 6.3 m³/h | 353 × 261 mm | 0.34 l |
| TPG-M 1¼″ | three-way mixing valve | 1¼″ | 45 / 85 kW | 10.3 m³/h | 471 × 296 × 160 mm | 1.1 l |
| TPG-MA 1″ | mixing + actuator with controller | 1″ | 20 / 40 kW | 6.3 m³/h | 353 × 261 mm | 0.34 l |
| TPG-MA 1¼″ | mixing + actuator with controller | 1¼″ | 45 / 85 kW | 10.3 m³/h | 471 × 296 × 160 mm | 1.1 l |
Actuator with controller (TPG-MA)
| Parameter | Value |
|---|---|
| Power supply | 230 V |
| Control | 3-point |
| Torque | 6 Nm |
| Running time 90° | 120 s |
| Protection | IP42 |
| Sensor | built-in temperature sensor |
| Setting | flow temperature is set directly on the controller |
| Certificates | CE, RoHS |
What's included
- Ball valves on flow and return with 0–120 °C thermometers
- Built-in check valve that prevents gravity circulation
- Shut-off valve for replacing the pump without draining the system
- Thermal insulation
- Union connections on flow and return
- Assembled and tested at the factory
HYDEO TD manifolds
Insulated manifolds for 2 to 8 circuits, with outlets upwards, downwards or both, and an additional side outlet.
General data
- Additional connection
- ½″ female thread
- Insulation
- included
- Mounting
- wall, brackets included
Series
| Series | Boiler connection | Circuit outlets | Centre distance | Output ΔT 10 / 20 K | Max. flow |
|---|---|---|---|---|---|
| TD Mini | 1″ | 1″ | 125 mm | 25 / 50 kW | 5.1 m³/h |
| TD 125 | 1¼″ | 1″ | 125 mm | 72 / 145 kW | 7.2 m³/h |
| TD 125 Plus | 1½″ | 1″ | 125 mm | 105 / 210 kW | 9.1 m³/h |
| TD 150 | 2″ | 1¼″ | 150 mm | 175 / 350 kW | 17.5 m³/h |
Available versions
| Series | Outlets upwards | Outlets downwards | Outlets upwards and downwards |
|---|---|---|---|
| TD Mini | 2 · 2+1 · 3+1 | – | 3 up + 1 down · 3 up + 2 down |
| TD 125 | 2+1 · 3+1 · 4+1 · 5+1 | 2+1 · 3+1 · 4+1 · 5+1 | 2+1 · 4+1 · 6+1 · 8+1 |
| TD 125 Plus | 2+1 · 3+1 · 4+1 · 5+1 | 2+1 · 3+1 · 4+1 · 5+1 | – |
| TD 150 | 2+1 · 3+1 · 4+1 · 5+1 | 2+1 · 3+1 · 4+1 · 5+1 | 2+1 · 4+1 · 6+1 · 8+1 |
2+1 means two circuits and one additional outlet.
What's included
- Thermal insulation
- Additional ½″ connection for a pressure gauge or sensor
- Wall brackets
- Combines directly with TPG pump groups
HYDEO TDS manifolds with separator
Hydraulic separator and manifold in one insulated housing. Takes up less space than a separately installed separator and manifold.
General data
- Circuit connection
- 1″
- Centre distance
- 125 mm
- Air vent
- ½″ female thread
- Dirt drain
- ½″ valve
- Additional connection
- ½″
- Mounting
- wall, brackets included
Series
| Series | Boiler connection | Output ΔT 10 / 20 K | Max. flow | Integrated separator |
|---|---|---|---|---|
| TDS Mini | 1″ | 25 / 50 kW | 5.1 m³/h | TSH 25 |
| TDS 125 | 1¼″ | 60 / 95 kW | 6.35 m³/h | TSH 60 |
Available versions
| Series | Outlets | Circuits |
|---|---|---|
| TDS Mini | 2 up + 1 side · 2 down + 1 side · 2 up + 1 down · 1 up + 1 down + 1 side | 2–3 |
| TDS Mini | 3 up + 1 side · 3 down + 1 side | 3 |
| TDS Mini | 4 + 1, up and down | 4 |
| TDS 125 | 2+1 · 3+1 · 4+1 · 5+1, up or down | 2–5 |
| TDS 125 | 2+1 · 4+1 · 6+1 · 8+1, up and down | 2–8 |
What's included
- Integrated hydraulic separator with air and dirt separation
- ½″ air vent and ½″ drain valve
- Thermal insulation
- Wall brackets
HYDEO TSH hydraulic separators
Separates the boiler circuit from the consumer circuits and removes air and dirt. Threaded versions for houses and flanged versions for large boiler rooms.
General data
- Body
- steel
- Air vent
- ½″
- Drain
- ½″ valve
- Sensor pocket
- ½″
- Insulation
- included
- Mounting
- wall · floor on flanged versions
Threaded versions
| Model | Connection | Output ΔT 10 / 20 K | Max. flow | Height | Width | Distance between connections | Volume |
|---|---|---|---|---|---|---|---|
| TSH 25 | 1″ male thread | 25 / 50 kW | 2.1 m³/h | 370 mm | 160 mm | 150 mm | 1.83 l |
| TSH 60 | 1¼″ male thread | 60 / 90 kW | 6.35 m³/h | 470 mm | 180 mm | 200 mm | 3.69 l |
| TSH 95 | 1½″ male thread | 95 / 145 kW | 9.25 m³/h | 550 mm | 220 mm | 240 mm | 6.22 l |
| TSH 150 | 2″ female thread | 150 / 250 kW | 14.3 m³/h | 665 mm | 240 mm | 300 mm | 13.3 l |
Flanged versions (TSH F)
| Model | Flange | Output ΔT 10 / 20 K | Max. flow |
|---|---|---|---|
| TSH F65 | 2½″ | 250 / 370 kW | – |
| TSH F80 | DN 80 · PN16 | 450 / 920 kW | 39.7 m³/h |
| TSH F100 | DN 100 | 650 / 1300 kW | 56.8 m³/h |
| TSH F125 | DN 125 | 900 / 1800 kW | 76.2 m³/h |
| TSH F150 | DN 150 | 1100 / 2200 kW | 95.1 m³/h |
TSH F80: height with stand 1200 mm, body diameter 270 mm, distance between flanges 500 mm, width 670 mm, depth 350 mm. Dimensions of the other flanged versions are given in the quote.
What's included
- Steel body with thermal insulation
- ½″ connection for an automatic air vent
- ½″ dirt drain valve
- ½″ pocket for a temperature sensor
- Wall brackets · floor stand on flanged versions
HYDEO BOX compact modules
Hydraulic separator and manifold for 2 or 3 circuits in one insulated block. BOX pump groups connect with 1½″ quick couplings.
General data
- Boiler connection
- 1″
- Group connection
- 1½″ quick coupling
- Max. pressure
- 10 bar
- Insulation
- XPE
- Group centre distance
- 100 mm
Modules
| Model | Circuits | Output ΔT 10 / 20 K | Height | Length |
|---|---|---|---|---|
| BOX 2 | 2 | 20 / 30 kW | 492 mm | 466 mm |
| BOX 3 | 3 | 20 / 30 kW | 492 mm | 676 mm |
BOX pump groups
| Group | Connection | Kvs | Output ΔT 10 / 20 K | Max. pressure / temperature | Pump length |
|---|---|---|---|---|---|
| BOX direct | 1″ · DN25 | 10.2 m³/h | 20 / 40 kW | 10 bar / 110 °C | 130 mm |
| BOX thermostatic 25–55 °C | 1″ · DN25 | – | 20 / 40 kW | 10 bar / 110 °C | 130 mm |
| BOX mixing | 1″ · DN25 | 6.3 m³/h | 20 / 40 kW | 10 bar / 110 °C | 130 mm |
| BOX with actuator and controller | 1″ · DN25 | 6.3 m³/h | 20 / 40 kW | 10 bar / 110 °C | 130 mm |
BOX pump groups are supplied separately from the module.
What's included
- Hydraulic separator and manifold in an assembled block
- XPE insulation
- 1½″ quick couplings for BOX groups
- Groups with shut-off valves, thermometers and check valve
Technical data are for guidance only and may be changed by the manufacturer. Exact values for the chosen version are confirmed in the quote.
Technical catalogue: hydraulic systems
All HYDEO pump groups, manifolds, separators and modules, with technical data for each version. Insulated metal housings for the boiler room.