HYDEO · Technical catalogue

Technical catalogue: hydraulic systems

All HYDEO pump groups, manifolds, separators and modules, with technical data for each version. Insulated metal housings for the boiler room.

Products with technical data by family

TPG

HYDEO TPG pump groups

Pre-assembled pump groups for one heating circuit, with 125 mm centre distance. They mount directly onto TD and TDS manifolds.

General data

Centre distance
125 mm
Operating pressure
up to 6 bar
Thermometers
0–120 °C
Heating medium
water or water-glycol
Pump installation length
130 mm (1″) · 180 mm (1¼″)
Circulation pump
of your choice
TPG-D · directTPG-M · mixing

Models

ModelTypeConnectionOutput ΔT 10 / 20 KKvsHeight × width × depthVolume
TPG-D 1″direct1″20 / 40 kW10.2 m³/h353 × 261 mm0.32 l
TPG-D 1¼″direct1¼″45 / 85 kW16.3 m³/h471 × 296 × 160 mm0.9 l
TPG-T 1″thermostatic valve 25–55 °C1″15 / 30 kW3.5 m³/h353 × 261 mm0.34 l
TPG-M 1″three-way mixing valve1″20 / 40 kW6.3 m³/h353 × 261 mm0.34 l
TPG-M 1¼″three-way mixing valve1¼″45 / 85 kW10.3 m³/h471 × 296 × 160 mm1.1 l
TPG-MA 1″mixing + actuator with controller1″20 / 40 kW6.3 m³/h353 × 261 mm0.34 l
TPG-MA 1¼″mixing + actuator with controller1¼″45 / 85 kW10.3 m³/h471 × 296 × 160 mm1.1 l

Actuator with controller (TPG-MA)

ParameterValue
Power supply230 V
Control3-point
Torque6 Nm
Running time 90°120 s
ProtectionIP42
Sensorbuilt-in temperature sensor
Settingflow temperature is set directly on the controller
CertificatesCE, RoHS

What's included

  • Ball valves on flow and return with 0–120 °C thermometers
  • Built-in check valve that prevents gravity circulation
  • Shut-off valve for replacing the pump without draining the system
  • Thermal insulation
  • Union connections on flow and return
  • Assembled and tested at the factory
TD

HYDEO TD manifolds

Insulated manifolds for 2 to 8 circuits, with outlets upwards, downwards or both, and an additional side outlet.

General data

Additional connection
½″ female thread
Insulation
included
Mounting
wall, brackets included
to pump groupsflowreturnmanifold 4 + 1 · 125 mm centres

Series

SeriesBoiler connectionCircuit outletsCentre distanceOutput ΔT 10 / 20 KMax. flow
TD Mini1″1″125 mm25 / 50 kW5.1 m³/h
TD 1251¼″1″125 mm72 / 145 kW7.2 m³/h
TD 125 Plus1½″1″125 mm105 / 210 kW9.1 m³/h
TD 1502″1¼″150 mm175 / 350 kW17.5 m³/h

Available versions

SeriesOutlets upwardsOutlets downwardsOutlets upwards and downwards
TD Mini2 · 2+1 · 3+1–3 up + 1 down · 3 up + 2 down
TD 1252+1 · 3+1 · 4+1 · 5+12+1 · 3+1 · 4+1 · 5+12+1 · 4+1 · 6+1 · 8+1
TD 125 Plus2+1 · 3+1 · 4+1 · 5+12+1 · 3+1 · 4+1 · 5+1–
TD 1502+1 · 3+1 · 4+1 · 5+12+1 · 3+1 · 4+1 · 5+12+1 · 4+1 · 6+1 · 8+1

2+1 means two circuits and one additional outlet.

What's included

  • Thermal insulation
  • Additional ½″ connection for a pressure gauge or sensor
  • Wall brackets
  • Combines directly with TPG pump groups
TDS

HYDEO TDS manifolds with separator

Hydraulic separator and manifold in one insulated housing. Takes up less space than a separately installed separator and manifold.

General data

Circuit connection
1″
Centre distance
125 mm
Air vent
½″ female thread
Dirt drain
½″ valve
Additional connection
½″
Mounting
wall, brackets included
air ventdirt drainseparator + manifold in one housing

Series

SeriesBoiler connectionOutput ΔT 10 / 20 KMax. flowIntegrated separator
TDS Mini1″25 / 50 kW5.1 m³/hTSH 25
TDS 1251¼″60 / 95 kW6.35 m³/hTSH 60

Available versions

SeriesOutletsCircuits
TDS Mini2 up + 1 side · 2 down + 1 side · 2 up + 1 down · 1 up + 1 down + 1 side2–3
TDS Mini3 up + 1 side · 3 down + 1 side3
TDS Mini4 + 1, up and down4
TDS 1252+1 · 3+1 · 4+1 · 5+1, up or down2–5
TDS 1252+1 · 4+1 · 6+1 · 8+1, up and down2–8

What's included

  • Integrated hydraulic separator with air and dirt separation
  • ½″ air vent and ½″ drain valve
  • Thermal insulation
  • Wall brackets
TSH

HYDEO TSH hydraulic separators

Separates the boiler circuit from the consumer circuits and removes air and dirt. Threaded versions for houses and flanged versions for large boiler rooms.

General data

Body
steel
Air vent
½″
Drain
½″ valve
Sensor pocket
½″
Insulation
included
Mounting
wall · floor on flanged versions
from boilerto circuitsboiler returncircuit return

Threaded versions

ModelConnectionOutput ΔT 10 / 20 KMax. flowHeightWidthDistance between connectionsVolume
TSH 251″ male thread25 / 50 kW2.1 m³/h370 mm160 mm150 mm1.83 l
TSH 601¼″ male thread60 / 90 kW6.35 m³/h470 mm180 mm200 mm3.69 l
TSH 951½″ male thread95 / 145 kW9.25 m³/h550 mm220 mm240 mm6.22 l
TSH 1502″ female thread150 / 250 kW14.3 m³/h665 mm240 mm300 mm13.3 l

Flanged versions (TSH F)

ModelFlangeOutput ΔT 10 / 20 KMax. flow
TSH F652½″250 / 370 kW–
TSH F80DN 80 · PN16450 / 920 kW39.7 m³/h
TSH F100DN 100650 / 1300 kW56.8 m³/h
TSH F125DN 125900 / 1800 kW76.2 m³/h
TSH F150DN 1501100 / 2200 kW95.1 m³/h

TSH F80: height with stand 1200 mm, body diameter 270 mm, distance between flanges 500 mm, width 670 mm, depth 350 mm. Dimensions of the other flanged versions are given in the quote.

What's included

  • Steel body with thermal insulation
  • ½″ connection for an automatic air vent
  • ½″ dirt drain valve
  • ½″ pocket for a temperature sensor
  • Wall brackets · floor stand on flanged versions
BOX

HYDEO BOX compact modules

Hydraulic separator and manifold for 2 or 3 circuits in one insulated block. BOX pump groups connect with 1½″ quick couplings.

General data

Boiler connection
1″
Group connection
1½″ quick coupling
Max. pressure
10 bar
Insulation
XPE
Group centre distance
100 mm
3 circuits

Modules

ModelCircuitsOutput ΔT 10 / 20 KHeightLength
BOX 2220 / 30 kW492 mm466 mm
BOX 3320 / 30 kW492 mm676 mm

BOX pump groups

GroupConnectionKvsOutput ΔT 10 / 20 KMax. pressure / temperaturePump length
BOX direct1″ · DN2510.2 m³/h20 / 40 kW10 bar / 110 °C130 mm
BOX thermostatic 25–55 °C1″ · DN25–20 / 40 kW10 bar / 110 °C130 mm
BOX mixing1″ · DN256.3 m³/h20 / 40 kW10 bar / 110 °C130 mm
BOX with actuator and controller1″ · DN256.3 m³/h20 / 40 kW10 bar / 110 °C130 mm

BOX pump groups are supplied separately from the module.

What's included

  • Hydraulic separator and manifold in an assembled block
  • XPE insulation
  • 1½″ quick couplings for BOX groups
  • Groups with shut-off valves, thermometers and check valve

Technical data are for guidance only and may be changed by the manufacturer. Exact values for the chosen version are confirmed in the quote.